Description
The further evolution of the FLOOR and more flooring system with ventilation holes adds decisive advantages to the well-known properties of the standard flooring system. The number of holes with a diameter of 13 mm (0.5) is variable, making it possible to realize free air percentage of 10%, 13% and 16%.
Applying floor coverings suited for seepage ventilation creates an "invisible room air-conditioning system". In modern office construction with smooth surfaces, the reverberation time is positively reduced when FLOOR and more components with perforation for ventilation are used. An additional combination with absorbent ceilings provides decisive advantages in room acoustics. |
Field of application
Projects with short construction times
Renovation projects
Training and conference rooms
Office areas
Areas with high sound-absorption requirements
Areas with concealed ventilation
|
Special features
Low weight per unit area
No drying times
Can be walked on immediately
Substructure adjustable in height
Compatible with other flooring systems such as cavity-type and access floors
Suited for room air-conditioning systems
Suited for noise absorption systems
|
Floor coverings
|
Textile coverings and loosely laid tiles suited for seepage ventilation
|
System specifications
| System designation |
Floor and more |
| Type |
FMP36-10A FMP36-13A FMP36-16A |
FMP36-10B FMP36-13B FMP36-16B |
FMP40-13A FMP40-13A FMP40-16A |
| Description |
 |
| Panel/material |
Calcium sulphate panel with profiled edges and perforations for ventilation 0.5 (13 mm) in Ø1 |
| Dimensions |
600 x 600 mm (23.6x23.6) |
| Panel thickness |
36 mm (1.42) |
40 mm (1.58) |
| System weight1 |
51 kg/m2 (10.45 lbs/ft2) |
54 kg/m2 (11.6 lbs/ft2) |
Substructure With construction heights > 500 mm (19.7) |
Steel pedestals RO stringers |
| Construction height2 |
74 800 mm (2.91 31.5) |
72 800 mm (2.84 31.5) |
| Load capacity rating (Nominal load) |
See STATICS supplement |
Fireproofing3 Building-material rating of the panel Fire-resistance rating |
A (non-combustible) |
A (non-combustible) |
Perforation type R10 R13 R16 |
Free air percentage 10% 13% 16% |
| Suitability of covering |
Textile coverings and loosely laid tiles suitable for seepage ventilation |
| Sound absorption4 |
Degree of absorption |
Absorption rating |
Degree of absorption |
Absorption rating |
| R 16 with needle-punched nonwoven |
0.50 |
D |
0.50 |
D |
| R 16 with velours |
0.40 |
D |
0.40 |
D |
| R 16 with needle-punched nonwoven and cavity insulation |
0.55 |
D |
0.55 |
D |
| Suitability of coverings |
Textile coverings, Elastic coverings, Loosely laid tiles, with Parquet/Unfinished parquet applied by the factory, Stone |
Ventilation diagram: Floor and more FMP36 with floor covering |
Ventilation diagram: FloorR and more FMP40 with floor covering |
 |
 |
Floor and more FMP36-16 with velour carpet (type: DLW, Premier Queen) Rated degree of sound absorption αw = 0.40 (LH) |
Floor and more FMP36-16 with needlefelt carpet (type: Forbo, Titan) Rated degree of sound absorption αw = 0.50 (LH) |
 |
 |
FLOOR and more FMP36-16 with needlepunch carpet (type: Forbo, Titan) and cavity insulation Rated degree of sound absorption
αw = 0.55 (LH) |
|
 |
|