Introduction of modules

Wiring Ducts and Trunking

Access Floors

Wire Mesh Cable Trays

Production Shutdown



 
Catalog


SHT-NM40/50 Basic Introduction


Main Characteristics of SHT-NM40/50
Remotely monitoring, controlling and managing function:
Keep the original state;
Set the limiting value to alarm;
System automatic alarm;
Daisy-chain;
Record the alarm;
User management

Alarming Methods of Hyperline SHT-NM:
The indicator on NM controlling panel flashes and the buzzer alarms;
The indicator on the PC interface flashes and the buzzer alarms;
Automatically send E-mail to system administrator
Software system:
Windows desktop controlling software system is single user operating system which need install and access by:
RS232;
TCP/IP


SHT-NM40/50 Technical Performance Form
Main function Technical instruction Product classification
Monitor Control
A C D
Monitoring Total load current + + +
Load current of each outlet     +
On/Off state of each outlet   + +
System operating state + + +
Temperature/Humidity + + +
Smog sensor + + +
Door/water logging sensor + + +
Controlling On/Off of each outlet   + +
Set the interval time of outlets' sequential on/off   + +
Set the on/off time of each outlet   + +
Keep the original state Keep the original state of each outlet when reset   + +
Set the limiting value to alarm The limiting range of total load current + + +
The limiting range of the load current of each outlet     +
The limiting range of temperature and humidity + + +
System automatic alarm The total load current exceeds the limiting value + + +
The load current of individual outlet exceeds the limiting value     +
Temperature/Humidity exceeds the limiting value      
System goes wrong + + +
Smog + + +
Water-logging/Door opening + + +
Alarming method The indicator on NM controlling panel flashes and the buzzer alarms
The indicator on the PC interface flashes and the buzzer alarms
Automatically send E-mail to system administrator
Daisy-chain Daisy-chain 10 pcs at most
Log record Alarming record can be queried
User management Set use's right
Software system In WINDOWS system (single user operating system)
Accessing method By TCP/IP
By RS232

Input/Outlet Characteristics
Main function Item Parameter
SHT-NM40 SHT-NM50
Input characteristic Rated input voltage 110/220VAC 50/60 Hz 380VAC 50/60 Hz
Input standard IEC60309 industrial plug/IP44
Cable length 3m (9.8 ft)
Max load current 32A 3x32A
Outlet characteristic Outlet socket standard
Outlet quantity 12, 16, 20, 24 12, 18, 24
On/Off state of each outlet LED displays
Rated outlet voltage 110/220VAC 220VAC
Max total load current 32A 3x32A
Sensor port Temperature/Humidity sensor port 1
Smog sensor port 1
Door/water logging sensor port 1
Mounting method Vertical Occupying 0U rack space
Case color Color Black
Fitting COM9/RJ45-G2 connecting line 2m (6.6 ft)
RJ45/RJ45-M2 connecting line 2m (6.6 ft)
Driver CD (one piece)
Instruction one set
Optional fitting Sensor Temperature/Humidity sensor
smog sensor
door sensor
water logging sensor
COM9/RJ45-B2 connecting line 2m (6.6 ft)

 

 
e-mail: info@hyperline.com